Model |
TG-NA10 TG-NA20 TG-NA30 TG-NA40 |
Number of light beam |
8/16....../80 4/8/16......80 4/6/8/10......80 4/6/8/10......80 |
Distance between light beam |
10mm 20mm 30mm 40mm |
Protection height |
Distance*(light beam-1) |
Detect distance |
0-1.2mm 0.5-5mm 0.5-5mm 0.5-5mm |
Min detecting object |
15mm 25mm 35mm 45mm |
Power supply |
12-24V DC |
Power consumption |
- |
Response time |
<5W |
Votlage(Not commend) |
<12ms |
Synchronization method |
Light synchronization, close to the first beam of the source line |
Safety level |
Conforms to the fourth level of safety standards of the International Electrotechnical Commission IEC61496-1/2 |
Output |
Two line NPN or two line PNP independent output |
Output current |
100mA |
Short circuit protection |
Equipment |
Indicator of emitter |
Alarm:Power on self-check, found that the output loop is disconnected, the green light ?ashing |
Indicator of receiver |
Power: When the power is on, the red indicator lights up.
Output: When the output is turned on, the yellow indicator light is on. |
IP code |
IP40 |
Structure |
Housing: Aluminum alloy End cap: ABS plastic; Bracket cold rolled steel |
Ambient Temp |
-10℃~50℃(No condensation,No icing) |
Ambient Humidity |
15-85%RH |
Ambient illuminance |
Sunshine:30000Lux Incandescent lamp:3000Lux |
Environment vibration |
Acceleration 300m/s,Two hours in each of the X,Y, and Z directions |
Environment compact |
Frequency:10-55Hz Amplitude:0.75mm ,Two hours in each of the X,Y, and Z directions |